FLOORS:
2″x 8″, 24-25W. 2″ x 10″, 26-28W, 2″x12″ 30-32W
2″x10″ @ 2nd Floor
Solid Wood Bridging
Double Perimeter Band Joists
3/4″ AdvanTech Decking – glued w/ ring shank nails
3/4″ 5 Ply Underlayment in all Vinyl Areas

WALLS:
2″x6″ -Exterior Walls – !6″ O.C. w/ dbl top plate
1/2″ CDX Plywood Extenor Wall Sheathing
House Wrap on all Ext Walls including Dormers
2″x 4″ Interior Walls – 16″ O.C.
1/2″ Drywall Painted (Represented as primed)
Blocking @ 48″ on Extenor Wills – Mate Walls

ROOF & CEILING:
6 / 12 Roof Pitch – Rafter Roofs @ 16″ O.C. Colonials & Ranches
12/12 Roof Pitch- Rafter Roofs @ 16″ O.C. Capes
8′ Ceiling Height
1/2″ CDX Plywood Roof Sheathing
Architectural Shingles – 30 Year self-sealing
Shingle Underlayment – Ice & Water Shield
Shingle over Ridge Vent
10-1/2″ Front & Rear Overhangs
1/2″ Drywall with RC-2 Channel Painted (Represented as primed)

KITCHEN:
Merillat – Spnng Valley Oak (Square)
Post-formed Laminate Countertop w/ 290 wrap
8″ Double Bowl Stainless Steel Sink
Single Lever Faucet w/Spray
Vented Range Hood on exterior walls
6″ Recessed Light @ Kitchen Sink

BATHROOMS:
Merillat – Spring Valley Oak (Square)
Post-formed Laminate Countertop w/290 wrap
Self-rimming China Sink & Single Lever Faucet
16″ Beveled Edge, Recessed Medicine Cabinet
Towel Bar. Towel Ring & Paper Holder
Bath Fan / Light Combination
One Piece Fiberglass Tub / Shower Unit
1.6 Gal. Elongated Water Saver Toilets

EXTERIOR:
Harvey ” Vicon”, Vinyl, Double Hung, Low-E Argon
Windows w/ Gnlles Between Glass
Mainstreet Vinyl Siding – Colonial D/4
Vented Vinyl Soffit & Aluminum Fascia
Shutters @ Front Elevation
3′ 0″ lnsulated Fiberglass 6 Panel @ Front
2′ 8″ lnsulated Fiberglass 9 Lite @ Rear
Hard Wired Door Chimes at Front Door

INSULATION:
R-38 Fiberglass Ceiling Insulation, (Ranch & Colonial)
R-38 Fiberglass Ceiling Insulation to Knee Walls Rafter Roofs
(No Insulation below Floor Decking)
R-19 Exterior Wall Insulation (Kraft Faced)
R-l I Basement Stair Wall Insulation
Insulated Window & Door Jambs

INTERIOR:
Armstrong Initiator “No Wax” Vinyl – Kitchen & Baths
Shaw Carpet – Stain resistant w /6# Bonded Pad
6 Panel H/C Passage Painted White (3 Hinge)
Pivacy Locks – Bedrooms & Baths (Brushed Nickel)
Colonial Baseboard & Casing – Painted White
Cased Marriage Wall Openings
Window Sills Thru-out

PLUMBING:
Copper Fresh Water Supply L ines
Shut-Off* on all Sinks & Toilets
Anti-Scald Devices on Showers & Tub/Showers
PVC Drain, Waste & Vent Lines
All Plumbing Stubbed Through Floor for Onsite Connection
2″ Future Vent – All Models
3″ Radon Vent from basement up through roof

ELECTRIC:
200 AMP. Full Size. Entrance Panel Box @ Kitchen Box Circuit
& Receptacle for Kitchen Range (220V)
AC/DC Smoke Detectors per code I – ship loose for Basement
Exterior GFI Receptacles per code (2) Locations
Light Fixtures -“Seagull” Brushed Nickel Interior, Antique Brass -Exterior
Arc Fault Circuit in each Bedroom per Code
Oue Switched Receptacle per Bedroom @ far corner
Note: No Thermostat Offered with Home
Wired only. One Location Per Floor

HEAT:
Hot Water Baseboard (stubbed through floor)